Home » Electrical » Power Factor Meters » PIECAL 334 4-20 mA Loop Calibrator
PIECAL 334 4-20 mA Loop Calibrator
- Easy to use
- Large display with Bar graph
- Long battery life
- Rugger boot & rugged switches
- NIST Calibration certificate included with every unit
Part Number:
PIECAL 334
In Stock?
Stock may be available
please call (877)766-5412 to confirm
please call (877)766-5412 to confirm
Quantity
Price:
$649.00
USD (change)




The PIECAL 334 is an easy to use
4-20 mA Loop Calibrator you can use to check, calibrate and measure all
your current signal instruments in a 4 to 20 milliamp DV loop.
The PIECAL 334 gives you the ability to:
To learn more about these competitive differences, download the PIECAL 334/334Plus vs. Altek 334A/334 sheet.
The PIECAL 334 gives you the ability to:
- Calibrate Milliamp Instruments - Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA; Read 0.00 to 52.00 mA, -99.99 to 99.99 V Simulate 2-Wire Transmitters; Power & Read 2-Wire Transmitters
- Calibrate with Confidence - Accurate to ±0.025% of Span at 4.000 & 20.000 EZ-CHECK outputs
- Use in the Plant, Field or Shop - Includes Rubber Boot and Attached Test Leads; Low profile switches resist accidental damage
- Simple Battery Changes - Separate compartment for no-tool battery changes with four inexpensive “AA” batteries
PIECAL Calibrators Competitive Edge
PIECAL Calibrators are designed and built by members of the same team that designed and built the calibrators manufactured by Fluke under the Altek label.To learn more about these competitive differences, download the PIECAL 334/334Plus vs. Altek 334A/334 sheet.
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- Easy to use
- Backlit display
- Source milliamps
- Monitor changes with bar graph
- Power saving output
- Calibrate using loop power
- Read loop current
- Power & measure 2 wire transmitters
- Evolutionary design
| General | |
| Operating Temperature Range | -20 to 60°C (-5 to 140F) |
| Storage Temperature Range | -30 to 60°C (-22 to 140F) |
| Relative Humidity Range | 10 % ≤RH ≤90% (0 to 35C), Non-condensing |
| 10% ≤RH ≤70% (35 to 60C), Non-condensing | |
| Size (L x W x H) | 5.63 x 3.00 x 1.60 in (143 x 76 x 41mm) |
| Weight | 12.1 oz, 0.34 kg (including boot & batteries) |
| Batteries | Four "AA" Alkaline 1.5V (LR6) |
| Optional NiMh Rechargeable battery kit | 120VAC for North America Only; charger, four NiMh batteries, AC & DC cords |
| Lower Battery | Low battery indication with nominal hour of operation left |
| Protection against misconnection | Over-voltage protection to 135 vrms (rated for 30 seconds) |
| Display | High contrast graphic liquid crystal display with 0.315" (8.0mm) high digits. |
| Read mA | |
| Ranges and Resolution | 0.00 to 52.000 mA or -25.00 to 300.00% of 4.-20 mA |
| Accuracy Below 24.010 mA Above 24.010 mA | ≤ ± (0.05% of 24.000mA +0.01 mA) ≤ ± (0.05% of 24.000mA +0.01 mA) |
| Voltage burden | ≤ 2V at 50 mA |
| Overload/Current limit protection | 54 mA nominal |
| Battery life | ≥ 125 Hours nominal |
| Source/Power & Measure Two Wire Transmitters | |
| Ranges and Resolution | 0.000 to 24.000 mA or -25.00 to 125% of 4-20mA |
| Accuracy EZ-Checks at 4 & 20 mA1 0.000 to 24.000 mA | ≤ ± (0.01 % of Span at 4 mA & 20 mA (±0.005mA) ≤ ± (0.05 % of 24 mA Span (±0.01mA) |
| Noise | ≤ ± 1/2 Least Significant Digit |
| Temperature effect | ≤ ± 0.005%/°C of FS |
| Loop compliance voltage | ≥ 24 DCV @ 20.00mA |
| Loop drive capability | 1200 Ω at 20 mA for 15 hours nominal |
| Battery life | ≥30 hours at 12 mA nominal |
1These are internal calibrated cardinal reference points and accuracy is not defined or limited by display resolution
| 2-Wire Transmitter Simulation | |
| Accuracy | Same as Source/Power & Measure |
| Voltage burden | ≤ 2V at 20 mA |
| Overload/Current limit protection | 24 mA nominal |
| Loop voltage limits | 2 to 100 VDC (fuse-less protected from reverse polarity connections) |
| Battery life | ≥ 125 hours nominal |
| Voltage Read | |
| Range and Resolution | -99.99 to +99.99 VDC Full Span (FS) |
| Accuracy | ≤ ± 0.05% of FS |
| Temperature effect | ≤ ± 100 ppm/°C of FS |
| Input resistance | ≥ 2 MΩ |
| Battery life | ≥ 125 hours nominal |
Product brochures
Technical documents
No user reviews available.