Home » AEMC L481 DC Voltage Logger
AEMC L481 DC Voltage Logger
Usually ships within 2 business days
Price: $379.00




The AEMC L481 Simple Logger® II is a single channel bipolar DC voltage recording device powered by alkaline batteries. It is capable of measuring voltages from – 850 to + 850VDC. The choice of data storage modes and storage rates allow the operator to effortlessly configure the logger to optimize memory usage to the application at hand.
Extended Recording Mode (XRM®) and delayed start time are just two of the many application friendly features in this logger. Internal memory allows storing over 240,000 measurements, more than enough for most data collection needs.
User programmable scale and engineering units are available. Battery operation and compact size allows for installation in tight locations without the need for external power. A series of front panel LEDs provide a quick status of the logger’s state and memory usage.
DataView® application software is included, providing real-time viewing of measurement data, even while recording. Instrument configuration, data storage and report generation from a pre-defined template or operator custom designed templates are also standard features.
What's Included:
Extended Recording Mode (XRM®) and delayed start time are just two of the many application friendly features in this logger. Internal memory allows storing over 240,000 measurements, more than enough for most data collection needs.
User programmable scale and engineering units are available. Battery operation and compact size allows for installation in tight locations without the need for external power. A series of front panel LEDs provide a quick status of the logger’s state and memory usage.
DataView® application software is included, providing real-time viewing of measurement data, even while recording. Instrument configuration, data storage and report generation from a pre-defined template or operator custom designed templates are also standard features.
Features
- Bipolar voltage recording up to ±850Vdc
- 64 samples per cycle (Model L261)
- Programmable storage rates from 8 every second to 1 every day
- 3 user selectable storage modes
- Stores up to 240,000 measurements in non-volatile memory
- Powered by standard Alkaline batteries
- Lightweight, compact, fits anywhere
- 5 LED indicators quickly and clearly display Logger status
- Includes DataView® software FREE for data storage, real-time waveform display, analysis and report generation
- Isolated USB communication cable included
- EN 61010-1; 300V CAT IV; 600V CAT III
Applications
- Rail voltage monitoring
- Long term supply monitoring
- Find intermittent voltage problems
- Machine monitoring
- Windmill monitoring
What's Included:
- Set of two color-coded 5ft voltage leads and color-coded alligator
clips (red/black) Cat. #2140.62
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
| ELECTRICAL | |
| Channels | One |
| Input Connection | Two recessed 4mm safety banana jacks |
| Measurement Range | ±850Vdc |
| Resolution | 0.1V |
| Accuracy | 0 to 5V: unspecified 5 to 50V: ± (0.5% of Reading + 1V) 50 to 850V: ± 0.5% of Reading + 0.5V) |
| Sample Rate | 8 samples/storage interval |
| Storage Rate | Programmable from 125ms to 1 day |
| Storage Modes | Start/Stop, FIFO and Extended Recording Mode (XRM™) |
| Recording Length | 15 minutes to 8 weeks, programmable using DataView® |
| Memory | 240,000 measurements (512KB) - The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed. |
| Communication | USB 2.0 optically isolated |
| Power Source | 2 x 1.5V AA-cell Alkaline batteries (included) |
| Battery Life | 100 hours to >45 days (dependent on sample rate and recording length) |
| MECHANICAL | |
| Dimensions | 4.94 x 2.75 x 1.28" (125 x 70 x 32mm) |
| Weight (with battery) | 6.4 oz (181 grams) |
| Case | UL94-V0 |
| Vibration | IEC 68-2-6 (1.5mm, 10 to 55Hz) |
| Shock | IEC 68-2-27 (30G) |
| Drop | Drop IEC 68-2-32 (1m) |
The DataView data logger software configures and control the power
analysis tests of your AEMC data logger from you PC-based computer.
DataView Features
• Display and Analyze Real-Time Data on PC
• Record Real-Time to PC
• Configure all Data Logger Functions and Parameters
• Display Waveforms, Trend Graphs, Harmonics (AC Models) and Text Summaries All Real-Time
• Print Custom and Standard Reports and Templates
Requirements:
DataView Features
• Display and Analyze Real-Time Data on PC
• Record Real-Time to PC
• Configure all Data Logger Functions and Parameters
• Display Waveforms, Trend Graphs, Harmonics (AC Models) and Text Summaries All Real-Time
• Print Custom and Standard Reports and Templates
Requirements:- Windows XP /
Windows Vista / Windows 7 (32/64 bit)
- 256MB of RAM for Windows XP
- 1GB of RAM for Windows Vista & Windows 7 (32 bit)
- 2GB of RAM for Windows Vista
& Windows 7 (64 bit)
- 80MB of hard disk space (200MB recommended )
- CD-ROM drive
Product brochures
No user reviews available.