Home » Electrical » Power Factor Meters » Transmation 1048 DC Process Signal Calibrator
Transmation 1048 DC Process Signal Calibrator
Part Number:
TRAN 1048
In Stock?
Stock may be available
please call (877)766-5412 to confirm
please call (877)766-5412 to confirm
Quantity
Price:
$2587.00
USD (change)



The Transmation 1048 DC Process Signal Calibrator will check, calibrate and measure all your current signal instruments in a 4 to 20 or 10 to 50 milliamp loop plus source and measure DC Volts.
Use at every point in your loop. Source & read 0.00 to 52.00 mA, simulate a 2-wire transmitter or use the Transmation 1048 to supply loop power while measuring your 2-wire transmitters. Toggle the display to show milliamps or percent span.
Stroke valves, calibrate recorders and digital indicators or any other intruments that get their input from a 4 to 20 or 10 to 50 mA loop. Easily set any value to within 0.01 mA
with the numeric keypad.
Calibrate recorders, analyzers and other instruments with 0 to 100 mV, 0 to 1, 1 to 5 or 0 to 10 Volt inputs. Easily set any value to within 0.01 mV or 0.001V with the
numeric keypad.
Easily store up to nine setpoints per range. Instantly change the output by recalling any stored setpoint.
Automatically step through some or all of the nine stored setpoints with dwell time from 5 to 500 seconds. Plus manual stepping for full control during instrument calibration.
Check loop wiring and receivers by using the Transmation 1048 in place of a 2-wire transmitter. Simulate a changing process input to check loop response and control settings.
Check controller outputs or measure the milliamp signal anywhere in the loop. The Transmation 1048 measures 0.00 to 52.00 mA signals with much greater accuracy than a typical multimeter. Toggle the display to show milliamps or percent of span.
Simultaneously measure the output of a 2-wire transmitter while using the interal loop supply to power the transmitter. Handy for checking transmitters in the field or on the bench.
Check loop power supplies, batteries or any DC voltage in the plant from 0.00 to 90.00 mV, 0.000 to 20.000 V and 0.00 to 48.00 V.
What's Included:
Use at every point in your loop. Source & read 0.00 to 52.00 mA, simulate a 2-wire transmitter or use the Transmation 1048 to supply loop power while measuring your 2-wire transmitters. Toggle the display to show milliamps or percent span.
Stroke valves, calibrate recorders and digital indicators or any other intruments that get their input from a 4 to 20 or 10 to 50 mA loop. Easily set any value to within 0.01 mA
with the numeric keypad.
Calibrate recorders, analyzers and other instruments with 0 to 100 mV, 0 to 1, 1 to 5 or 0 to 10 Volt inputs. Easily set any value to within 0.01 mV or 0.001V with the
numeric keypad.
Easily store up to nine setpoints per range. Instantly change the output by recalling any stored setpoint.
Automatically step through some or all of the nine stored setpoints with dwell time from 5 to 500 seconds. Plus manual stepping for full control during instrument calibration.
Check loop wiring and receivers by using the Transmation 1048 in place of a 2-wire transmitter. Simulate a changing process input to check loop response and control settings.
Check controller outputs or measure the milliamp signal anywhere in the loop. The Transmation 1048 measures 0.00 to 52.00 mA signals with much greater accuracy than a typical multimeter. Toggle the display to show milliamps or percent of span.
Simultaneously measure the output of a 2-wire transmitter while using the interal loop supply to power the transmitter. Handy for checking transmitters in the field or on the bench.
Check loop power supplies, batteries or any DC voltage in the plant from 0.00 to 90.00 mV, 0.000 to 20.000 V and 0.00 to 48.00 V.
What's Included:
- 1 pair of test leads with banana plugs and alligator clips
- Rubber Boot
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- Calibrates all milliamp instruments - Source 4 to 20 and 10 to 50 milliamps; Simulate two-wire transmitters; Read milliamp outputs; Power & measure two-wire transmitters
- Calibrates voltage instruments - Source 0.00 to 100.00 mV and 0.000 to 10.000 VDC; Measure 0.00 to 90.00 mV, 0.000 to 20.000 and 0.0 to 48.0 VDC
- Rugged and reliable - Rubber boot for protection in the plant
- Easy to use - One touch to set the output & function
- Accuracy to ±0.015% - Within ±0.02 mA from 4 to 20 mA; Within ±0.004 V from 0 to 10V
- Long lasting alkaline batteries - Four “AA” Alkaline cells for easy replacement
- Nine setpoints for each range - Automatically or manually step the output
- Milliamp or percent display - Source or Read from 0.00 to 52.00 mA or in percent of 4 to 20 and 10 to 50 mA span
Product brochures
No user reviews available.