AEMC 2620 Current Leakage Probe

Usually ships within 2 business days
AEMC 2620
Manual

Price: $549.00

Quantity
Request a Quote
Ask an Expert



The Model 2620 measures leakage current shunted to ground caused by insulation faults. It enables the operator to locate failures when they occur, or anticipate them before they occur, without shutting down equipment or spending hours troubleshooting.

It is designed specifically for locating low current faults on high current loads. The detector is a sensitive nickel alloy AC current transformer capable of measuring differential or leakage current as low as 500ľA, and may be used to measure current up to 400A continuous duty.

The Model 2620 provides two output ranges: 1mV/mAac or 1mV/Aac. The output leads are terminated with standard 4mm banana plugs capable of interfacing with any standard multimeter. With its 4" jaw opening and range of 500ľA to 200A, the Model 2620 provides a versatile way to analyze unbalanced current measurements, leakage values on grounding conductors and ground loop currents.

Applications:
  • Preventive maintenance
  • Equipment troubleshooting on electrical distribution systems
  • High accuracy low-current measurements
  • Measure fault currents on three-phase, three-wire systems
  • Industrial troubleshooting checks

The Good:


The Bad:


The Bottom Line:

Full Review

Very high sensitivity
Differential or leakage current from 500ľA
Current up to 400A
Two switch-selectable measurement ranges: 4AAC / 400AAC
Large inside jaw diameter allows use on large or multiple conductors
Work with single-, dual- and three-phase networks
Connect directly to DMMs on mV or Vac range

Product manuals

No user reviews available.

Have a Question?

Do you have a question for us? Can't find what you're looking for? We're glad to help you. Fill out the simple form below and we'll get back to you as soon as possible.

Name
Email
Phone
Message
In order to prevent spam through the form, please enter the passcode word displayed below. If you cannot read the word clearly, you can change the passcode image.

Enter Passcode: