The Fluke i2000flex AC Current Clamp increases the current measurement range of your Fluke digital multimeter.

The Fluke i2000flex is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation and measurement of odd-shaped objects without breaking the circuit.

Used in conjunction with multimeters, recorders, data loggers, power quality analyzers, or oscilloscopes.
  • Three ranges: 20A, 200 A & 2000 A, 1 mV, 10 mV or 10 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600V safety rating

The Good:


The Bad:


The Bottom Line:

Full Review


Electrical specifications
Current ranges

20 A

200 A

2000 A

AC rms
Output sensitivity (AC-coupled)

100 mV

10 mV

1 mV

1 mV per A
Load impedance

100 kΩ minimum
Accuracy
at +25 C 1 % of range (45 Hz to 65 Hz)
Linearity
10 % to 100 % of range 0.2 % of reading
Noise

8 mV ac rms (30 A)

2 mV ac rms (300 A, 3000 A)
Frequency range

10 Hz to 20 kHz (-3 dB)
Phase error

< 1 (45 Hz to 65 Hz)

10 (at 20 kHz)
Position sensitivity
with cable > 25 mm from the coupling 2 % of range
External field
with cable > 200 mm from the head 1 % of range
Power supply

2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient

0.08% of reading perC
Working voltage
see Safety standards section 600 V AC rms or DC

General Specifications
Head cable length (double insulated)

610 mm (24 in)
Head cable diameter

14.3 mm (0.56 in)
Head bend radius

38.1 mm (1.5 in)
Cable length (head to electronics)

2 m (6.56 ft)
Output connection

Molded 4 mm safety plugs (not integrated)
Operating temperature range

0 C to +70 C (32 F to 158 F) (head and electronics)
Storage temperature range

-40 C to +105 C (-40 F to 221 F) (head)

-20 C to +85 C (-4 F to 185 F) (electronics)
Operating humidity

15 % to 85 % (non-condensing)
Weight

180 g (6.34 oz) (head)

190 g (6.70 oz) (electronics)
Safety standards

EN 61010-1: 2001

EN 61010-2-032: 2002

EN 61010-031: 2002

600 Vrms, Category III, Pollution Degree 2

Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
EMC standards

EN 61326: 1998 +A1, A2, & A3
Dimensions
HxWxD 116 mm x 68.5 mm x 30 mm (4.56 in x 2.69 in x 1.18 in)