Home » Dent CON-0150-U Clamp-On CT 150A
Dent CON-0150-U Clamp-On CT 150A
Sorry, this product is discontinued and is no longer available for purchase. Please call 1-877-766-5412 to find a suitable replacement.Dent 150A EZ Clamp Current Transformer is a suggested replacement model.




Clamp-on current transformers are the one-hand operating solution for temporary or long-term studies. They are designed to work in tight places and clamp around bus bars.
DENT’s energy monitoring components are used for a variety of applications, including building automation, tenant submetering, performance verification, energy management and new technology assessment.
DENT’s energy monitoring components are used for a variety of applications, including building automation, tenant submetering, performance verification, energy management and new technology assessment.
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- Current ranges include 2.0A to 150A; 10 to 600A; 10.0 to1200A AC
- Output Signal: 333 mV @ Maximum Input
- Working Voltage : 600Vrms
ELECTRICAL SPECIFICATIONS
Nominal Rating: 150A
Useful Current Range: 2 to 150A AC
Output Signal: 2.22 mV/A; 333mV @ 150A AC
Accuracy: 2 to 80A: 1% Reading; 80 to 150A: 1.5% Reading
Phase Shift: 2 to 20A: ≤ 3°; 20 to 80A: ≤ 2°; 80 to 150A: ≤ 2.5°
Frequency Range: 40 Hz to 10 kHz
MECHANICAL SPECIFICATIONS
Dimensions: 14 x 5 x 3 cm (5.5 x 2.0 x 1.2”)
Maximum Cable/Bus Bar: Cable Diameter 2 cm (0.8”); Bus bar 20 x 5 cm (0.8 x 0.2”)
Polarity: Red lead is positive
Output Lead: Double insulated, 3 m (10 ft )
Operating Temperature: -10° to 55°C (14° to 130°F )
OTHER FEATURES
Jaw Opening: 2.0 cm (0.8”)
Weight: 180 g (6.5 oz)
Dielectric Strength: 5550V, 50/60 Hz between primary, secondary and the outer case of the handle
Storage Temperature: -40° to +70°C (-40° to 160°F)
Case Protection: IP 40 (IEC 529)
Drop Test: Test per IEC 68-2-32: 1.0 m drop on 38 mm of oak on concrete
Mechanical Shock: Test per IEC 68-2-6
Common Mode Voltage: 30 Vrms
SAFETY SPECIFICATIONS
Working Voltage: Maximum 600 Vrms
CE Mark: Extra insulation between electrical parts and handle; conforms to IEC 1010-2-032
Nominal Rating: 150A
Useful Current Range: 2 to 150A AC
Output Signal: 2.22 mV/A; 333mV @ 150A AC
Accuracy: 2 to 80A: 1% Reading; 80 to 150A: 1.5% Reading
Phase Shift: 2 to 20A: ≤ 3°; 20 to 80A: ≤ 2°; 80 to 150A: ≤ 2.5°
Frequency Range: 40 Hz to 10 kHz
MECHANICAL SPECIFICATIONS
Dimensions: 14 x 5 x 3 cm (5.5 x 2.0 x 1.2”)
Maximum Cable/Bus Bar: Cable Diameter 2 cm (0.8”); Bus bar 20 x 5 cm (0.8 x 0.2”)
Polarity: Red lead is positive
Output Lead: Double insulated, 3 m (10 ft )
Operating Temperature: -10° to 55°C (14° to 130°F )
OTHER FEATURES
Jaw Opening: 2.0 cm (0.8”)
Weight: 180 g (6.5 oz)
Dielectric Strength: 5550V, 50/60 Hz between primary, secondary and the outer case of the handle
Storage Temperature: -40° to +70°C (-40° to 160°F)
Case Protection: IP 40 (IEC 529)
Drop Test: Test per IEC 68-2-32: 1.0 m drop on 38 mm of oak on concrete
Mechanical Shock: Test per IEC 68-2-6
Common Mode Voltage: 30 Vrms
SAFETY SPECIFICATIONS
Working Voltage: Maximum 600 Vrms
CE Mark: Extra insulation between electrical parts and handle; conforms to IEC 1010-2-032
Product brochures
Technical training
No user reviews available.